5. Configuring the Receiver

Technical Reference Manual-4.0.0en

Pressing DEVCE (F5) allows the
device to be chosen.

System 500 supports several devices
such as Leica Disto memo, Disto pro,
Disto

TM

pro

4

and Disto

TM

pro

4

a. All of

them are hand held lasermeter that
can be used to record otherwise
inaccessible points. You may also use
a simple tape to measure to such
points and input the measurements
manually.

Press CONT (F1) to return to the
previous panel.

Dist Offset - Enter a distance offset if
necessary. Refer to Appendix H for
more information.

Hgt Offset - Available if Include Hgt
in the previous panel and Use Device
in the current panel are set to YES.
The options are:

None - Neither instrument nor target
height is considered. The result is the
delta height between the center of the
external device and the aimed point.
This delta height can be measured,
estimated or left as zero.
Inst Height - The instrument height is
considered. If the delta height
between the center of the external
device and the aimed point is
measured or estimated, the result is
the height difference between the
rover point on the ground and the
aimed point. Enter the instrument
height into the corresponding new
line.
Inst Height & Trgt Height -
Instrument as well as target height to
be considered. If the delta height
between the center of the external
device and the aimed point is
measured or estimated, the result is
the ground height difference between
rover and aimed point. Enter the
values in the corresponding two new
lines.

Refer to Appendix H for a complete
list of all supported Hidden Point
devices, their configurations,
sketches and more information on
hidden points.