10 using the near key, 11 graph, 10 using the near key 7.5.11 graph – Leica Geosystems GPS System 500 - Technical Reference Manual User Manual

Page 218

Advertising
background image

218

7. Measuring with System 500

Technical Reference Manual-4.0.0en

7.5.10 Using the NEAR key

The nearest point to the current
sensor position for staking out can be
found by pressing SHIFT and then
NEAR (F2). The current sensor
position is the position at the time
when the NEAR key is pressed.

It may also help when using this key
to set the stake out filter to Points to
Stake. See chapter 11.3 for more
information about the filter.

Stop the search with ABORT (F1).

Once the nearest point has been
found, its point ID is automatically
copied into the field of the Target
Point.

Stake out the point as usual.

7.5.11 Graph

A map of the 30 last measured points
can be displayed by pressing SHIFT
and then GRAPH (F3). Each point is
given a temporary ID between 1 and
30.

SCALE (F2) displays a linear scale
consistent with the current zoom
level.

The map is displayed. Use ZOOM+
(F3) and ZOOM- (F4) to zoom in and
out.

ID (F5) reveals a list with the tempo-
rary point IDs and the “real” point IDs.

Advertising