7. Measuring with System 500

Technical Reference Manual-4.0.0en

The graphical display is a square until
the 0.5m level is reached. At this
stage it will turn into a circle.

When you are at the point to be
staked, the measurements to the
point must be at or nearly zero. Make
sure that the pole is level and press
OCUPY (F1). If you had to level the
pole, ensure that the measurements
to the point are still good before
pressing OCUPY.

Depending upon what has been set in
the configuration, the following screen
may appear.

The Point Id of the Target Point will be
taken by default. If you wish to enter a
new point Id you may, but remember
that this will then be considered a
separate point. If you simply wish to
add aditional text to the suggested
point Id, press Enter. The point Id in
the display remains and the cursor
will be in the position defined in the
current Point Id template.

If required, you may also add a code
(if a coding system has been
configured). Details on adding codes
are given in section 7.4.4.

When you are satisfied with the input,
press STOP (F1).

The DIFF (F2) key is available.

Pressing this key gives the
differences between the design
coordinates and staked coordinates
of the point.