Leica Geosystems GPS System 500 - Technical Reference Manual User Manual

Page 97

Advertising
background image

97

5. Configuring the Receiver

Technical Reference Manual-4.0.0en

STOP P-PRC - Defines the method
used for Auto Stop when Auto Stop is
set to YES.
When Auto Stop is set to NO a
percentage value will be displayed
next to the Time or Epochs in the
Main Survey screen. This indicates
how much of the Auto Stop criteria
has elapsed. The Auto Stop criteria is
defined using the P-PRC (F5) key
(see below).

END Survey - Defines how the
survey will be ended. Manual lets you
exit the survey yourself. Automatic
will exit the survey automatically.
Auto & Shut-down will exit the
survey and turn the sensor off.

When one of the STOP P-PRC
options is selected the P-PRC (F5)
key will become available. Pressing
this key will enable you to configure
the option you have selected.

# of Sats is selected, set the length of
time to observe depending on the
number of satellites available. You
may edit the value for each number of
satellites. Should the number of
available satellites change during
observations, the observations
already recorded will be taken into
account. Should the number of
satellites decrease, more time will be
added. Should the number of satel-
lites increase, time will be subtracted.
The Receiver stops recording when
the time limit is reached.

Press CONT (F1) to return to
CONFIGURE\Occupation Settings.

When:

Time is selected, set the required
observation time for each point. The
time starts counting when OCUPY is
pressed. The Receiver stops record-
ing when the set length of time is
reached.

STOP&GO Indicator is selected, set
the baseline range. When measuring,
an observation time will be calculated
based on the selected baseline
range, the number of available
satellites and the GDOP. This is
displayed as a percentage value.

Observations is selected, set the
number of epochs that should be
recorded at each point.

Advertising