14 slope stake-out - procedure – Leica Geosystems GPS System 500 - Technical Reference Manual User Manual

Page 222

Advertising
background image

222

7. Measuring with System 500

Technical Reference Manual-4.0.0en

If Diff Check has been set to either
Position only, Height only or Pos +
Hgt
in the CONFIGURE\ Stake-Out
screen then the STAKE-OUT\ Occupy
Differences panel will be displayed
automatically if the differences
exceed the defined Limit.

Diff In/Out - Horizontal distance In/
Out to the Target Point.
Diff Left/Right - Horizontal distance
Left/Right to the Target Point.
Diff Cut/Fill - Vertical distance to the
Target Point.
Total Diff - Length of vector from
Target Point to measured point.

If you have chosen to record a LONG
log file these values will also be
stored in the log file.

Press STORE (F1)

A check will be performed according
to the Required Coordinate Quality
set in the Configuration. If the point is
within the Required CQ, it will be
stored and no special messages will
appear.

If however the point is outside the
Required CQ, it may warrant further
investigation.

7.5.14 Slope Stake-Out - Procedure

Slope Stake-Out has two main
applications.