7. Measuring with System 500

Technical Reference Manual-4.0.0en

Initialization on the Fly without
starting time
This is the method that will be
preferred by SR520 and SR530
users. No Static Initialization is
required. Observations will be
recorded as soon as CONT (F1) in
the SURVEY\Begin screen is
pressed.

Recording Distinct Points without
starting time
To record distinct points within the
moving part of the kinematic chain
(whether a static initialization has
been performed or not), occupy the
point, level the pole and press
OCUPY (F1). The point will be
recorded in accordance with what has
been defined in the Configuration Set.
Check the Point Id and Antenna
Height. Add a code if required. Press
STOP (F1) followed by STORE (F1)
to store the point.

Initialization and point recording
with starting time
After entering a point ID, the antenna
height and a start time, press the
OCUPY (F1) key.

The line Start Time changes to Time
to go
. The time before the
measurement starts automatically is
displayed in hours:minutes:seconds
and is counted down.

Once the entered start time is
reached, the measurement beginns.

The line Time to go changes to
Static Obs/Time.

When the required length of time has
passed, press the STOP (F1) key to
stop raw observation recording. If
Auto Stop has been set in the
Configuration, this will happen
automatically.

Press STORE (F1) to store the Point
Id and any Thematical Code that you
may have assigned. If Auto Store has
been set in the Configuration, this will
happen automatically.