Chapter 3 Wiring

3.1 Positioner Mode 1 (Standard

Type)

94

3.1.2 PIO Pattern Select and PIO Signal

[1] PIO Pattern (Control Pattern) Selection

There are three ways of control methods for ERC3 controllers. Set the most suitable PIO pattern

to Parameter No.25 “PIO Pattern Select”.

Refer to 4.2.2 Operation in Positioner Mode 1 for the details of PIO patterns.

Type

Value set in

parameter

No.25

Mode

Overview

PIO

Pattern 0

0

(at the

delivery)

8-point type

x

Number of positioning points : 8 points

x

Position command : binary code

x

Zone signal output

*1

: 1 point

PIO

Pattern 1

1

3-point type

(Solenoid valve

type)

x

Number of positioning points : 3 points

x

Position command : Individual number signal ON

x

Zone signal output : None

PIO

Pattern 2

2

16-point type

x

Number of positioning points : 16 points

x

Position command : binary code

x

Position zone signal output

*2

or Zone signal

output

*1

: 1 point

(Note 1)

Note 1 The position zone signal output can be switched to the zone signal with Parameter

No.149.

*1 Zone signal output



Zone range is to be set to either Parameter No.1, 2 and it is

always available after the home-return operation is complete.

*2 Position zone signal output This feature is associated with the specified position number.

The zone range is set in the position table. The zone range is

enabled only when the position is specified but disabled if

another position is specified.