Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

315

(17) PIO pattern selection (Parameter No.25)

No.

Name

Symbol

Unit

Input Range

Default factory setting

25 PIO pattern selection

IOPN

0 to 5

0 (Standard Type)

Select the PIO operation pattern in Parameter No.25.

For the details of PIO patterns, refer to 4.2 Operation in Positioner Mode.

[For Positioner Mode 1]

Type

Value set in

parameter

No.25

Mode

Overview

PIO

Pattern 0

0

(at the

delivery)

8-point type

x

Number of positioning points : 8 points

x

Position command : binary code

x

Zone signal output

*1

: 1 point

PIO

Pattern 1

1

3-point type

(Solenoid valve type)

x

Number of positioning points : 3 points

x

Position command : Individual number signal ON

x

Zone signal output : None

PIO

Pattern 2

2

16-point type

x

Number of positioning points : 16 points

x

Position command : binary code

x

Position zone signal output*

2

or Zone signal

output*

1

: 1 point

(Note 1)

*1 Zone signal output



Zone range is to be set to either Parameter No.1, 2 and it is

always available after the home-return operation is

complete.

*2 Position zone signal output : This feature is associated with the specified position number.

The zone range is set in the position table. The zone range is

enabled only when the position is specified but disabled if

another position is specified.

Note 1 The position zone signal output can be switched over to the zone signal output with

the setting of Parameter No.149.