IAI America ERC3 User Manual

Page 90

Advertising
background image

Chapter 2 Installation

2.3 How to Install

80

• When Using Foot Brackets (Option)

When installing the unit with using the foot brackets, use the T slots as for the direct installation

and affix with hex socket head cap screws.

Actuator

Type

A B C D

E

Recommended

attachment screw Tightening Torque [N•m]

RA4C

71 57 20 10 I6.6 through

hole

M6

5.36

RA6C

95 79 25 12 I9 through hole

M8

11.48

Regarding attachment screws

• Use of high-tension bolts meeting at least ISO-10.9 is recommended.

• For the effective engagement length between the bolt and female thread, provide at least the

applicable value specified below:

Female thread is made of steel material ĺ Same length as the nominal diameter

Female thread is made of aluminum ĺ 1.8 times of nominal diameter

Caution: Pay attention when selecting screws. If a bolt out of the instruction is used, it may

cause damage on tapped holes or unexpected accident or failure due to insufficient

strength on the actuator attachment.

C

D

E

A

B

Advertising