Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

304

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse Train Control Mode

[1] I/O Parameter List

The categories in the table below indicate whether parameters should be set or not. There are

five categories as follows:

A : Check the settings before use.

B : Use parameters of this category depending on their uses.

C : Use parameters of this category with the settings at shipments leaving unchanged as a

rule. Normally they may not be set.

D : Parameters of the category are set at shipment in accordance with the specification of the

actuator. Normally they may not be set.

E : Parameters of the category are exclusively used by us for convenience of production.

Changing their settings may not only cause the actuator to operate improperly but also to

be damaged. So, never change the setting of the parameters.

Category do not appear on the teaching tool.

Also, the unused parameter numbers are not mentioned in the list.

No.

C

at

eg

or

y

Name

Symbol

Unit

Input Range

Default factory

setting

For

Positioner

Mode 1

For

Positioner

Mode 2

For Pulse

Train

Mode

Relevant

sections

This section

1 B Zone 1+

ZNM1

mm

-9999.99 to

9999.99

Actual stroke on +

side

(Note1)

{

{

[2] (1),

[2] (68)

2 B Zone 1-

ZNL1

mm

-9999.99 to

9999.99

Actual stroke on -

side

(Note1)

{

{

[2] (1),

[2] (68)

3 A Soft limit+

LIMM

mm

-9999.99 to

9999.99

Actual stroke on +

side

(Note1)

{

{

{

[2] (2)

4 A Soft limit-

LIML

mm

-9999.99 to

9999.99

Actual stroke on -

side

(Note1)

{

{

{

[2] (2)

5 D Home return direction

ORG

0: Reverse

1: Normal

In accordance with

actuator

(Note1)

{

{

{

[2] (3)

6 C Press & hold stop judgment period

PSWT

msec

0 to 9999

255

{

{

[2] (4)

7 C Servo gain number

PLGO

0 to 31

In accordance with

actuator

(Note1)

{

{

{

[2] (5),

[3]

8 B Default velocity

VCMD

mm/s 1 to Actuator’s

max. speed

Rated actuator

speed

(Note1)

{

{

[2] (6)

9 B Default acceleration/deceleration

ACMD

G

0.01 to actuator's

max. acceleration/

deceleration

Rated actuator's

acceleration/

deceleration

(Note1)

{

{

{

[2] (7)

10 B Default positioning width

INP

mm

0.01 to 999.99

0.10

{

{

{

[2] (8)

12 B Current-limiting value at standstill

during positioning

SPOW

%

1 to 70

35

{

{

{

[2] (9)

13 C Current-limiting value during home

return

ODPW

%

1 to 100

In accordance with

actuator

(Note1)

{

{

{

[2] (10)

15 B Pause input disable

FPIO

0: Enabling

1: Disabling

0

{

{

[2] (11)

16 B SIO communication speed

BRSL

bps

9600 to 230400

38400

{

{

{

[2] (12)

17 B Minimum delay time for slave

transmitter activation

RTIM

msec

0 to 255

5

{

{

{

[2] (13)

21 B Servo ON input disable

FPIO

0: Enabling

1: Disabling

0

{

{

[2] (14)

22 C Home return offset level

OFST

mm

0.00 to 9999.99

In accordance with

actuator

(Note1)

{

{

{

[2] (15)

23 B Zone 2+

ZNM2

mm

-9999.99 to

9999.99

Actual stroke on +

side

(Note1)

{

[2] (1)

24 B Zone 2-

ZNL2

mm

-9999.99 to

9999.99

Actual stroke on -

side

(Note1)

{

[2] (1)

25 A PIO pattern selection

IOPN

0 to 5

0

(Standard Type)

{

{

{

[2] (17)

26 B PIO jog velocity

IOJV

mm/s 1 to Actuator’s

max. speed

100

{

[2] (18)

Note 1 The setting values vary in accordance with the specification of the actuator. At shipment, the

parameters are set in accordance with the specification.