1 connecting example – IAI America ERC3 User Manual
Page 401
Chapter 10
Appendix
10.2 W
ay to Set Multiple Controllers with 1
Teaching
Tool
391
10.2.1 Connecting Example
Caution: Supply 0V to the SIO converter and each controller from the same power
source.
Teaching Pendant
To be prepared by customer.
Cable included in PC software
<RCB-CV-MW, CB-RCA-SIO□□□>
<CB-SEL-USB030, RCB-CV-USB, CB-RCA-SIO□□□>
PC Software
(Option)
RS232C-compatible <RCM-101-MW>
USB-compatible <RCM-101-USB>
SIO Converter (with Terminal Resistor)
<RCB-TU-SIO-A> Vertical
<RCB-TU-SIO-B> Horizontal
e-CON Connector (Manufactured by AMP 4-1473562-4 : Housing Color Green)
e-CON Connector (Manufactured by AMP 3-1473562-4 : Housing Color Orange)
Junction (Manufactured by AMP 5-1473574-4)
GN
GN
GN
Terminal Resistance
R = 220Ω
Controller Link Cable
<CB-RCB-CTL002>
Axis No. Setting : 0
Axis No. Setting : n-1
Axis No. Setting : 1
1st unit
nth unit
2nd unit
PIO Converter
PIO Converter