Chapter 3 Wiring

3.3 Positioner Mode 2 (Extension

Type by PIO Converter)

110

[2] PIO Patterns and Signal Assignment

The signal assignment of cable by the PIO pattern is as shown below. Follow the following

table to connect the external equipment (such as PLC).

Parameter No.25 (PIO Pattern) Selection

0

1

2

Category

PIO Functions

Positioning mode

Teaching mode

256-point mode

Number of positioning

points

64 points

64 points

256 points

Home return signal

{

{

{

Jog signal

u

{

u

Teaching signal

(Current position writing)

u

{

u

Input

Brake release

{

u

{

Moving signal

{

{

u

Zone signal

{

u

u

Pin No. Wire

Color

Output

Position zone signal

{

{

{

1A

BR-1

2A

RD-1

3A

OR-1

4A

YW-1

5A

GN-1

IN0

PC1

PC1

PC1

6A

BL-1

IN1

PC2

PC2

PC2

7A

PL-1

IN2

PC4

PC4

PC4

8A

GY-1

IN3

PC8

PC8

PC8

9A

WT-1

IN4

PC16

PC16

PC16

10A

BK-1

IN5

PC32

PC32

PC32

11A

BR-2

IN6

MODE

PC64

12A

RD-2

IN7

JISL

PC128

13A

OR-2

IN8

JOG+

14A

YW-2

IN9

BKRL

JOG-

BKRL

15A

GN-2

IN10

16A

BL-2

IN11

HOME

HOME

HOME

17A

PL-2

IN12

*STP

*STP

*STP

18A

GY-2

IN13

CSTR

CSTR/PWRT

CSTR

19A

WT-2

IN14

RES

RES

RES

20A

BK-2

Input

IN15

SON

SON

SON

1B

BR-3

OUT0

PM1(ALM1)

PM1(ALM1)

PM1(ALM1)

2B

RD-3

OUT1

PM2(ALM2)

PM2(ALM2)

PM2(ALM2)

3B

OR-3

OUT2

PM4(ALM4)

PM4(ALM4)

PM4(ALM4)

4B

YW-3

OUT3

PM8(ALM8)

PM8(ALM8)

PM8(ALM8)

5B

GN-3

OUT4

PM16

PM16

PM16

6B

BL-3

OUT5

PM32

PM32

PM32

7B

PL-3

OUT6

MOVE

MOVE

PM64

8B

GY-3

OUT7

ZONE1

MODES

PM128

9B

WT-3

OUT8

PZONE/ZONE2

PZONE/ZONE1

PZONE/ZONE1

10B

BK-3

OUT9

11B

BR-4

OUT10

HEND

HEND

HEND

12B

RD-4

OUT11

PEND

PEND/WEND

PEND

13B

OR-4

OUT12

SV

SV

SV

14B

YW-4

OUT13

*EMGS

*EMGS

*EMGS

15B

GN-4

OUT14

*ALM

*ALM

*ALM

16B

BL-4

Output

OUT15

*ALML

*ALML

*ALML

17B

PL-4

18B

GY-4

19B

WT-4

20B

BK-4

Signal with “*” expresses the signal of active low.

PM1 to PM8 are the binary code output signals of an alarm while it is being generated. [Refer to 4.2.3 [5]]

PZONE (position zone signal) can be switched over to ZONE (zone signal) with the setting of Parameter

No.149.

(Reference) Signal of Active Low

Signal with “*” expresses the signal of active low. A signal of active low is a signal that the input signal is

processed when it is turned OFF, output signal is ordinary ON while the power is ON, and turns OFF

when the signal is output.