Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

318

(20) Default movement direction for excitation-phase signal detection (Parameter No.28)

No.

Name

Symbol

Unit

Input Range

Default factory setting

28

Default movement direction

for excitation-phase signal

detection

PHSP

0 : Reversed

direction

1 : Forward direction

In accordance with

actuator

Excitation phase signal detection

(Note 1)

is executed at the first servo-on after the power is

supplied. Detection direction at this time is determined. Define the detection direction at this

time.

Even though it is generally unnecessary to change this setting, set this to the direction which

the motor is easy to move when the actuator interferes with the mechanical end or peripheral

object at the time the power is supplied.

If the direction not interfering is the same direction as the home return direction, set the same

values as set to Parameter No.5 Home Return Direction. If the direction is opposite, set the

other values from Parameter No.5. (If No.5 is 0, set 1. If No.5 is 1, set 0.)

Note 1 In Simple Absolute Type, the 2nd excitation phase signal detection is executed at the

home-return operation complete to establish the absolute home point.

(21) Excitation-phase signal detection time (Parameter No.29)



No.

Name

Symbol

Unit

Input Range

Default factory setting

29

Excitation-phase signal

detection time

PHSP

msec

1 to 999

In accordance with

actuator



Excitation phase signal detection

(Note 1)

is executed at the first servo-on after the power is

supplied. Detection direction at this time is determined. Define the detection direction at this

time.

It is not necessary to change this parameter in normal use, however, there are some cases that

adjustment of this parameter is enable for recovery when a problem such as the excitation

phase signal detection error or operation error is generated.

Contact us if it is necessary to change this parameter.

Note 1 In Simple Absolute Type, the 2nd excitation phase signal detection is executed at the

home-return operation complete to establish the absolute home point.



(22) Excitation detection type (Parameter No.30)



No.

Name

Symbol

Unit

Input Range

Default factory setting

30 Excitation detection type

PHSP

0 : Conventional

method

1 : New method 1

(For vertical

mount

installation)

2 : New method 2

(For horizontal

mount

installation)

0



Excitation phase signal detection

(Note 1)

is executed at the first servo-on after the power is

supplied, and in the new method, we succeeded to make this operation smoother and quieter

than ever (when compared in IAI products).

There is a risk that the slider or rod may drop at the excitation phase signal detection if setting

to “2” (New Method 1) and installing the actuator in vertical mount. Establish the setting

considering the posture of the installation. When the actuator is installed vertically, and if the

slide or rod drops, set to “0” (Basic Method).

Note 1 In Simple Absolute Type, the excitation detection is executed at the home-return

operation complete.