2 pio pattern selection and pio signal, 1] operation pattern – IAI America ERC3 User Manual

Page 134

Advertising
background image

Chapter 3 Wiring

3.4 MEC Mode 1 (Operation with PLC)

124

3.4.2 PIO Pattern Selection and PIO Signal

[1] Operation pattern

There are 2 types of operation patterns available. The selection of the operation patterns is to

be set in the initial setting process using a teaching tool such as the PC software. See the

instruction manual of each teaching tool for more details.

This setting cannot be made for Quick Teach.

Explained below is the outline of the operational specifications for each pattern.

Operation pattern

Description

How to connect motorized

cylinder

Air cylinder circuit

(Reference)

Stopping at

2 points

(2-point

positioning)

Movement

by

1

input

between

2

po

in

ts

[S

in

gl

e-

so

le

no

id

m

od

e]

You can move the actuator

between 2 points using the same

control you would normally use

with an air cylinder.

You can set the positions of the

end point and start point.

You can specify the moving

speed and

acceleration/deceleration. You

can also specify push-motion

Operation. The actuator moves

to the end point when the ST0

turns ON, and returns to the start

point when the signal turns OFF.

Detection of start position

LS0

Detection of end position

LS1

Move signal 1

ST0

ERC3

PLC

Power Supply

Move signal 1

ST0

Air cylinder

Sensor

Spring

P (Air)

Detection of start position

LS0

Detection of end position

LS1

PLC

R1

R2

B

Solenoid A

Air cylinder

Solenoid A

Solenoid B

Sensor

P (Air)

Move signal 1

ST0

Move signal 2

ST1

A

B

R1

R2

PLC

Detection of end position

LS1

Detection of start position

LS0

Movement

by

2

input

between

2

poi

nt

s

[D

ou

bl

e-

so

le

no

id

m

od

e]

Detection of start position

LS0

Detection of end position

LS1

PLC

Move signal 2

ST1

Move signal 1

ST0

ERC3

Power Supply

Detection of start position

LS0

Detection of end position

LS1

Air cylinder

Solenoid A

Solenoid B

Sensor

P (Air)

Move signal 1

ST0

Move signal 2

ST1

A

B

R

R

PLC

Stopping at

3 points

(3-point

positioning)

Movement

by

2

input

between

3

poi

nt

s

[3-poi

nt

positi

oning]

You can move the actuator

between 2 points using the same

control you would normally use

with an air cylinder.

You can set the positions of the

end point and start point.

You can set the position of an

intermediate point and perform

positioning to the intermediate

point.

You can specify the moving

speed and

acceleration/deceleration. You

can also specify push-motion

Operation. The actuator moves

to the end point when the ST1

turns ON, and moves to the start

point when the ST0 turns ON.

[Intermediate movement mode,

both ON]

When both the ST0 and ST1 are

turned ON, the actuator will

position to and stop at an

intermediate point.

When both the ST0 and ST1 are

turned OFF, the actuator will

stop in the middle of movement.

[Intermediate movement mode,

both OFF]

When both the ST0 and ST1 are

turned OFF, the actuator will

position to and stop at an

intermediate point.

When both the ST0 and ST1 are

turned ON, the actuator will stop

in the middle of movement.

Detection of start position

LS0
Detection of end position

LS1

Detection of

intermediate point

LS2

Move signal 1

ST0

Move signal 2

ST1

PLC

ERC3

Power Supply

Air cylinder

Sensor

P (Air)

PLC

Detection of end position

LS1

Detection of start position

LS0

P (Air)

P (Air)

Detection of

intermediate point

LS2

Move signal 1

ST0

Move signal 2

ST1

Advertising