Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

323

(35) PIO inch distance, PIO inch distance 2 (Parameter No.48, No.49)

No.

Name

Symbol

Unit

Input Range

Default factory setting

48 PIO inch distance

IOID

mm

0.01 to 1.00

0.1

49

(Note1)

PIO inch distance 2

IOD2

mm

0.01 to 1.00

0.1

Set the inching distance for the inching input command from PLC when PIO Pattern = 1

(Teaching Mode) is selected in Positioner Mode 2.

The maximum allowable value is 1 mm.

Note 1 Parameter No.49 “PIO inch distance 2” is not used.

(36) Load output judgment time period (Parameter No.50)

No.

Name

Symbol

Unit

Input Range

Default factory setting

50

Load output judgment time

period

LDWT

msec

0 to 9999

255

This parameter is not used.

(37)

Torque inspected range

(Parameter No.51)

No.

Name

Symbol

Unit

Input Range

Default factory setting

51 Torque inspected range

TRQZ

0 : Enabled

1 : Disabled

0

This parameter is not used.

(38) Default acceleration/deceleration mode (Parameter No.52)

No.

Name

Symbol

Unit

Input Range

Default factory setting

52

Default

acceleration/deceleration

mode

CTLF

0 to 2

0 (Trapezoid)

These values are automatically set to “Acceleration/Deceleration Mode” of the applicable

position number when the target position is written to the unregistered position table.

Set Value

Description

0

Trapezoid

1

S-motion

2

Primary delay filter