Chapter 2 Installation

2.3 How to Install

78

• There are tapped holes on the slider top for the load attachment. Also, there are two reamed

holes. Utilize the reamed holes when repeatability in the attachment after detaching is required.

Also, when a tuning of such accuracy as the perpendicularity is required, use only one of the

reamed holes.

• Shown below is the detail of the attachment area. Attach a load with the bolts listed in the table

below with the specified tightening torque. Pay special attention to the bolt length.

2-D

4-E

C

B ±0.05

Reamer Hole Pitch : ±0.02

A

Actuator

Type

A

B

C

D

E

Tapping

Diameter

Tightening

Torque [N•m]

SA5C

50 20.5 41 I4H7, depth 6

M4, depth 8

M4

1.76

SA7C

72

32 64 I5H7, depth 10 M5, depth 10

M5

3.42

Regarding attachment screws

• Use of high-tension bolts meeting at least ISO-10.9 is recommended.

• Make sure to have the length of at least 1.8 times to the bolt diameter below for the effective

length of screw engagement for the tightening of a bolt and a female screw.

Caution: Pay attention when selecting screws. If a bolt out of the instruction is used, it may

cause damage on tapped holes or unexpected accident or failure due to insufficient

strength on the actuator attachment.