25) torque filter time constant (parameter no.33), 26) press velocity (parameter no.34), 27) safety velocity (parameter no.35) – IAI America ERC3 User Manual

Page 330

Advertising
background image

Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

320

(25) Torque filter time constant (Parameter No.33)

No.

Name

Symbol

Unit

Input Range

Default factory setting

33 Torque filter time constant

TRQF

0 to 2500

In accordance with

actuator

This parameter decides the filter time constant for the torque command. When vibrations and/or

noises occur due to mechanical resonance during operation, this parameter may be able to

suppress the mechanical resonance. This function is effective for torsion resonance of ball

screws (several hundreds Hz).

(26) Press velocity (Parameter No.34)

No.

Name

Symbol

Unit

Input Range

Default factory setting

34 Press velocity

PSHV

mm/s 1 to actuator's max.

pressing speed

In accordance with

actuator

This is the parameter to set the velocity in pressing operation.

If a change to the setting is required, make sure to have the setting below the maximum

pressing velocity of the actuator. Setting it fast may disable to obtain the specified pressing

force. Also when setting at a low velocity, take 5mm/s as the minimum.

Velocity

Press Velocity

Positioning width

Work

Positioning Velocity

Caution: If the velocity of the positioning of the position table is set below this

parameter, the pressing speed will become the same as the positioning

speed.

(27) Safety velocity (Parameter No.35)

No.

Name

Symbol

Unit

Input Range

Default factory setting

35 Safety velocity

SAFV

mm/s

(deg/s)

1 to 250 (below

maximum speed)

100

This is the parameter to set the maximum speed of manual operation while the safety velocity

selected in the teaching tool. Do not have the setting more than necessary.

Advertising