Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.2 MEC Mode 1, MEC Mode 2 and MEC Mode 3

342

(6) Press velocity (Parameter No.7)

No.

Name

Symbol

Unit

Input Range

Default factory setting

7

Press velocity

PSHV

mm/s

0.01 to actuator's

max. pressing

speed

In accordance with

actuator

This is the parameter to set the velocity in pressing operation.

If a change to the setting is required, make sure to have the setting below the maximum

pressing velocity of the actuator. Setting it fast may disable to obtain the specified pressing

force. Also when setting at a low velocity, take 5mm/s as the minimum.

Velocity

Press Velocity

Positioning width

Work

Positioning Velocity

Caution: If the velocity of the positioning of the position table is set below this

parameter, the pressing speed will become the same as the positioning

speed.

(7) Press & hold stop judgment period (Parameter No.8)

No.

Name

Symbol

Unit

Input Range

Default factory setting

8

Press & hold stop judgment

period

PSWT

msec

0 to 9999

255

Judging completion of pressing operation

Monitoring the torque (current limit) set in “Pressing Force” in the operation condition table

in %, it turns ON the pressing complete signal PE* when the load current during pressing

operation comes to the following condition. PE* turns ON once the condition is satisfied even

if the work is not stopped.

(Accumulated time in which current reaches pressing value [%])

– (accumulated time in which current is less than pressing value [%])

• 255 ms (Parameter No.8)

Current

Time

Pressing [%]

Operation

start

Approach end

Pressing start

200ms

20ms

75ms

295ms

200ms + 75ms – 20ms • 255ms

Pressing complete (PENDoutput)

Contacting work

Decrease in current due

to movement of work

Advertising