Ɣ detailed category 2 circuit example – IAI America ERC3 User Manual

Page 413

Advertising
background image

Chapter 10

Appendix

10.3 Conformity to Safety Category

403

Ɣ Detailed category 2 circuit example

SG

SGA

SGB

RTS

CTS

EMG1-

EMG1+

EMG2-

EMG2+

EMB1-

EMB1+

EMB2-

EMB2+

DC24V+

DC24V-

EMBOUT

EMBIN

EMB2+

EMB2-

EMB1+

EMB1-

EMGOUT

EMGIN

EMG2+

EMG2-

EMG1+

EMG1-

1

2

3

4

5

6

7

8

9

MPI

MPO

EMGS

ENB

VP24

PIO Converter

TP Connection Detecting

TP Detection

T24V…Output

Bypass relay…OPEN

TP Not Detected

T24V…Not Output

Bypass relay…CLOSE

TP

Emergency Stop SW

Enable SW

Shell

1

2

3

13

14

9

12

6

5

23

24

25

22

7

26

12

11

10

9

8

7

6

5

4

3

2

1

Motor Power

Cutoff Relay

RCB-LB-TG

SGA

SGB

EMGA

T24V

EMGB

1

2

3

4

5

6

7

8

9

5V

+

Enable SW

Enable SW

Emergency Stop SW

Reset SW

Control

Circuit

Control

Circuit

Solenoid Contactor Solenoid Contactor

External Emergency

Stop Circuit category 1

24V

Motor Power Supply

S1

S2

EMG−

24V

R

Y

Advertising