Chapter 3 Wiring

3.7 Wiring Method

145

3.7.3 Wiring between PIO Converter and Host Controller (e.g. PLC)

The connection of I/O for PIO Converter is to be conducted with the dedicated I/O cable. The

cable length is shown in the model code of PIO Converter. Check the model code of PIO

Converter. Selection can be made from 3m or 5m as well as standard 2m. 10m is also

applicable at maximum if purchased separately. [Refer to 1.1.5 How to read the model]

Also, the end of the cable harness to be connected to the host controller (PLC, etc.) is just cut

and no treatment is conducted so the wiring layout can be performed freely.

Model: CB-PAC-PIOƑƑƑ

(ƑƑƑ indicates the cable length L. Example 020 = 2m)

Flat Cable (20-core) × 2

BK-4 (20B)

BR-3 (1B)
BK-2 (20A)

BR-1 (1A)

20A

20B

1A

1B

Half Pitch MIL Socket

HIF6-40D-1.27R (Hirose Electric)

A

B

L

No treatment

conducted

No treatment

conducted

No.

Cable

Color

Wiring

No.

Cable

Color

Wiring

1A

BR-1

1B

BR-3

2A

RD-1

2B

RD-3

3A

OR-1

3B

OR-3

4A

YW-1

4B

YW-3

5A

GN-1

5B

GN-3

6A

BL-1

6B

BL-3

7A

PL-1

7B

PL-3

8A

GY-1

8B

GY-3

9A

WT-1

9B

WT-3

10A

BK-1

10B

BK-3

11A

BR-2

11B

BR-4

12A

RD-2

12B

RD-4

13A

OR-2

13B

OR-4

14A

YW-2

14B

YW-4

15A

GN-2

15B

GN-4

16A

BL-2

16B

BL-4

17A

PL-2

17B

PL-4

18A

GY-2

18B

GY-4

19A

WT-2

19B

WT-4

20A

BK-2

Flat Cable

٤

A

(Press Welding)

AWG28

20B

BK-4

Flat Cable

٤

B

(Press Welding)

AWG28

For the signal assignment of each wire, refer to the following considering the operation mode.

1) Positioner Mode 2 ·············3.3.3 [3] PIO Circuit

2) MEC Mode 2 ·····················3.5.3 [3] PIO Circuit