Chapter 1 Specifications Check

1.2 Specifications

1.2.1

Actuator

36

1.2 Specifications

1.2.1 Actuator

[1] High Output Setting

(1) Enabling/Disabling of High Output Setting

This actuator can select whether to enable / disable the high output setting by the

parameters.

At the delivery, the high output setting is activated for all the controllers.

Controller Type

Parameter

Setting

Set Value

Enabled

1 (At the delivery)

CON Mode Type

No.152

High Output Setting

Disabled

0

Enabled

1 (At the delivery)

MEC Mode Type

No.28

High Output Setting

Disabled

0

1) The maximum speed, acceleration, and transportable weight differ when high output

setting is enabled and disabled.

[Refer to [3] Mechanical Specifications]



2) An operation with the duty 100% is available if the high output setting is inactivated. The

actuator cannot operate with 100% when it is activated.

Duty ratio is the rate of operation expressed in % that presents the time of the actuator

being operated in 1 cycle of operation.

D =

×100 [%]

 

Caution: Please note that the high output setting becomes invalid automatically if Quick

Teach is connected.

D : Duty

T

M

: Operation time (pressing operation included)

T

R

: Stop time

T

M

T

M

+T

R

Speed

Deceleration

Acceleration

Constant Speed

Stop

Operation time T

M

Stop time T

R

Time of one cycle