IAI America ERC3 User Manual

Page 341

Advertising
background image

Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

331

(63) Gain scheduling upper limit multiplying ratio (Parameter No.144)

No.

Name

Symbol

Unit

Input Range

Default factory setting

144 Gain scheduling upper limit

multiplying ratio

GSUL

%

0 to 1023

0 (Disabled)

Gain scheduling is the function to change the gain in accordance with the operation speed.

This parameter shows the multiplying rate of the upper limit of the changeable gain.

With the set multiplying rate, the values for GS Velocity Loop Proportional Gain (Parameter

No.145) and GS Velocity Loop Integrated Gain (Parameter No.146) are changed.

Set Value

Description

100 or less

Gain scheduling disabled

101 to 1023 Gain scheduling enabled

Set to 300 if enable

(64) GS velocity loop proportional gain (Parameter No.145)

No.

Name

Symbol

Unit

Input Range

Default factory setting

145 GS velocity loop proportional

gain

GSPC

1 to 30000

750

If the gain scheduling upper limit multiplying ratio (Parameter No.144) is set enabled, this

parameter setting becomes enable for the velocity loop proportional gain.

It is not necessary to change the setting in normal use.

(65) GS velocity loop integral gain (Parameter No.146)

No.

Name

Symbol

Unit

Input Range

Default factory setting

146 GS velocity loop integral gain

GSIC

1 to 500000

4500

If the gain scheduling upper limit multiplying ratio (Parameter No.144) is set enabled, this

parameter setting becomes enable for the velocity loop integral gain.

It is not necessary to change the setting in normal use.

(66) Total movement count threshold (Parameter No.147)

No.

Name

Symbol

Unit

Input Range

Default factory setting

147 Total movement count

threshold

TMCT

Times

0 to 999999999

0 (Disabled)

Notice will be made with Movement Counter Threshold Exceeding Alarm (04E) if the total

number of movement exceeds the value set in this parameter.

The judgment would not be made if the value is set to 0.

Advertising