Chapter 10

Appendix

10.2 W

ay to Set Multiple Controllers with 1

Teaching

Tool

390

10.2 Way to Set Multiple Controllers with 1 Teaching Tool

Settings of several controller units can be performed with 1 unit of teaching tool with the

method stated below if using PIO converter. ERC3 should be in CON Mode.

The following method cannot be applied if ERC3 is in the serial communication type.

It is usually necessary to connect the teaching tool to the controllers one by one when making a

setup to multiple controllers with one unit of teaching tool. In this section, explains how to

perform the settings without connecting and disconnecting the plug.

• Requisite devices :

(1) SIO Converter (RCB-TU-SIO-A or RCB-TU-SIO-B) : 1 unit

(2) Controller Link Cable (CB-RCB-CTL002)

: Required by the number of controllers

Accessories 1) 4-way junction (Manufactured by AMP 5-1473574-4)

: 1 unit

2) e-CON Connector (Manufactured by AMP 4-1473574-4) : 1 unit

3) Terminal Resistance (220:, with a e-CON connector)

: 1 unit

Instead of the e-CON cable attached to the controller link cable, a terminal block may be used.

In this configuration, disconnect the e-CON connector from the controller link cable.