Chapter 7 troubleshooting, 1 action to be taken upon occurrence of problem – IAI America ERC3 User Manual

Page 361

Advertising
background image

Chapter 7

Troubleshooting

7.1
Action to Be

Taken upon Occurrence of Problem

351

Chapter 7 Troubleshooting

7.1 Action to Be Taken upon Occurrence of Problem

Upon occurrence of a problem, take an appropriate action according to the procedure below in

order to ensure quick recovery and prevent recurrence of the problem.

1) Status LEDs and PIO Check on ERC3 and PIO Converter

[ERC3 main body]

{

: Illuminating × : OFF ڏ : Flashing

LED

Status of PIO Output Signal

CON Mode Type

MEC Mode Type

(GN) (RD)

Operation status

*ALM Output

(Note 1)

Control Power Supply ON

ON

Control Power Supply OFF

OFF

Ч

Ч

Servo OFF

OFF

Motor driving power supply

OFF

OFF

Emergency Stop

OFF

×

{

Alarm

(Operation cancellation level

or more)

OFF

{

×

Servo ON

ON

ڏ

×

During automatic servo-off

(Note 2)

ON

{

(OR)

In initializing process at

power being ON

OFF

Note 1 The output signals with * mark are the active low signals that turn ON in normal condition and turn

OFF while in abnormal condition.

Note 2 Servo-motor Auto OFF [Refer to Chapter 5 Power-saving Function]



[PIO converter]



{

: Illuminating × : OFF ڏ : Flashing

LED

Status of PIO Output Signal

CON Mode Type

MEC Mode

Type

SV

(GN)

ALM

(RD)

Operation status

SV Output

(Servo ON)

*ALM Output

(Note 1)

(Alarm)

*EMGS Output

(Note 1)(Note 2)

(Emergency

Stop Status)

*ALM Output

(Note 1)

Control Power Supply ON

OFF

ON

ON

ON

Control Power Supply OFF

OFF

OFF

OFF

OFF

Ч

Ч

Servo OFF

OFF

OFF

OFF

Motor driving power supply

OFF

OFF

OFF

OFF

Emergency Stop

OFF

OFF

OFF

OFF

×

{

Alarm

(Operation cancellation level

or more)

OFF

OFF

OFF

{

×

Servo ON

ON

ON

ON

ON

ڏ

×

During automatic servo-off

(Note 3)

OFF

ON

ON

{

(OR)

In initializing process at

power being ON

OFF

OFF

OFF

Note 1 The output signals with * mark are the active low signals that turn ON in normal condition and turn

OFF while in abnormal condition.

Note 2 *EMGS output is not prepared for Pulse Train Control Type.

Note 3 Servo-motor Auto OFF [Refer to Chapter 5 Power-saving Function]