9] switches used in test run, 10] switches used in alarm reset – IAI America ERC3 User Manual

Page 287

Advertising
background image

Chapter 4 Operation

4.5 Operation in MEC Mode 3 (T

est Run with Quick

Teach.)

277

[8] Switches and Rotary Knobs Used in Acceleration/Deceleration and Speed Settings

The speed to move and the acceleration/deceleration speed of the actuator to the forward,

backward and intermediate positions can be determined.

Twist Accel Dial and adjust at the desired

position. (Setting Range : 1 to 100%)

Registering

Acceleration/

Deceleration

(Valid in Manual

Mode)

Press SAVE Button. If the registration is

complete, a peep sound is made and the

save lamp turns ON.

(The setting is registered together with the

speed setting.)
Twist Speed Dial and adjust at the desired

position. (Setting Range : * to 100%)

(* It differs depending on the actuator.)

Registering Speed

(Valid in Manual

Mode)

Press SAVE Button. If the registration is

complete, a peep sound is made and the

save lamp turns ON.

(The setting is registered together with the

acceleration setting.)

[9] Switches Used in Test Run

Performing

Continuous Operation

(Valid in Manual

Mode)

Press RUN Button and a continuous

operation is started.

If set to 2-point positioning, the continuous

operation is performed in the order of end

point ĺ start point ĺ end point.

If set to 3-point positioning, the continuous

operation is performed in the order of

intermediate point ĺ end point ĺ start

point ĺ intermediate point.

The operation lamp flashes while in the

continuous operation.

Stopping Continuous

Operation

(Valid in Manual

Mode)

Press STOP Button and the operation

stops.

Once it is stopped, the stop lamp turns ON.

[10] Switches Used in Alarm Reset

Alarm Reset

(Valid in Manual

Mode)

Press and hold STOP button.

Reset the alarm.

Advertising