Chapter 3 Wiring

3.2 Pulse

Train Control Mode

103

[3] List of PIO Signals

The table below lists the functions of PIO signals. Refer to the section shown in Relevant

Sections for the details of the control of each signal.

Category

Signal

Abbreviation

Signal Name

Function Description

Relevant

Sections

EMG

Emergency Stop Input It shuts the motor power supply.

4.3 [3]

BK

Brake Forcible Release The brake will forcibly be released.

4.3 [4]

PP

/PP

Differential Pulse Train

Input (+)

NP

/NP

Differential Pulse Train

Input (-)

Input the pulse train from the host controller.

4.3 [7]

SON

Servo ON

Servo is ON while this signal is turned ON.

4.3 [6]

TL

Torque Limit Select

Applies torque limit to the motor with the signal on and the

value set to the parameter.

4.3 [7]

HOME

Home Return

The controller will perform home return operation when

this signal is turned ON.

4.3 [6]

When Parameter No. 25 = 0 (Positioning mode)

An alarm will be reset when this signal is turned ON.

4.3 [6]

RES

Reset

When Parameter No. 25 = 1 (Pressing mode)

Alarm reset is conducted with this signal being ON when

TL signal is not ON.

4.3 [6]

Input

DCLR

Deviation Counter Clear Have the deviation counter reset with this signal being

ON.

4.3 [7]

SV

Servo ON Status

This signal will remain ON while the servo is ON.

4.3 [6]

INP

Positioning Completion

It is turned ON when the remaining movement pulse

amount in the deviation counter is in the positioning width

range.

4.3 [6]

TLR

Torque Under Control Turns ON when torque reaches the limit while in torque

restriction (TL signal is ON).

4.3 [7]

HEND

Home Return

Completion

This signal will turn ON when home return has been

completed.

It will be kept ON unless the home position is lost.

4.3 [6]

Output

*ALM

Alarm

Turns ON when the controller is in normal condition, and

turns OFF when an alarm is generated.

4.3 [6]

Signal with “*” expresses the signal of active low. It is ON when the power is applied to the controller, and turns OFF when

the signal is output.

Caution: Torque restriction by TL Signal is available even if Parameter No.25 = 0. Thus, it is

possible to have a positioning move with the torque restricted in such cases as when

pushing out a breakable work piece. However, when it comes to a situation that the

actuator cannot move, it may create a big deviation (servo lag pulses) as it may

occur for the pressing control. If TL Signal is turned off under this condition, the

operation may be started with the maximum torque at the same time, and make a

sudden move. If it is not to be used, set User Parameter No.61 Torque Restriction

Command Input to invalid (= 1).

If Parameter No.25 = 0, the deviation counter cannot be cleared since there is no

DCLR Signal. Move to the opposite side or turn the servo OFF if a movement cannot

be made any more.