Chapter 7

Troubleshooting

7.2 Fault Diagnosis

356

[In the case of Pulse Train Control Mode]

Situation

Possible cause

Check/Treatment

In spite of inputting

pulse-train to the

controller, the actuator

does not move.

PIO signal processing or parameter

setting is incorrect.

1) Servo OFF state

2) The pause signal is OFF.

3) The pulse-train type, a parameter, is

selected incorrectly.

4) The positive/negative logic of

pulse-train, a parameter, is selected

inversely.

5) The unit moving distance per pulse,

which is a setting condition of

electronic gear ratio, a parameter, is

too small.

1) Is Status LED on ERC3 turned ON

in green?

If PIO Converter is used, is Status

LED turned ON in green?

[Refer to Name for Each Parts and

Their Functions]

Turn ON the servo-on signal SON of

PIO.

2) Operation is available when PIO

pause signal *STP is ON and pause

when it is OFF. Turn it ON. [Refer to

Chapter 3, 3.2.2.]

3) Check the pulse train type.

[Refer to Chapter 4, 4.3 [8] (2)

Format Settings of Command Pulse

Train.]

4) Check the positive/negative logic of

pulse-train. (Host units supplied by

some manufacturers have

positive/negative logic opposite to

our logic. Reverse the logic setting

and try the operation.)

[Refer to Chapter 4, 4.3 [8] (2)

Format Settings of Command Pulse

Train.]

5) Do not make the unit moving

distance less than the resolution of

the encoder. The actuator does not

move unless pulses by the

resolution of the encoder are input.

[Refer to Caution in Chapter 4, 4.3

[8] (1) Electrical Gear Setting]

(Note) In case of 3) or 4), the actuator

may not sometimes operate

smoothly.

You may not find case 5) when

the actuator is moved for a long

distance at a high frequency.

(Note) Refer to Chapter 3 Wiring for PIO signal.