Chapter 4 Operation

4.2 Operation in Positioner Mode

4.2.2 Operation in Positioner Mode 1

193

 

Caution: (1) The speed during tension operation is set in Parameter No.34. The

pressing operation speed is 20mm/s. The speed for pulling operation is

same as that for pressing operation. Do not set any value larger than the

value in the list.

If the speed setting in the position table is below this set value, pressing is

performed with the set speed.

(2) The tension ready position should be the tension start position or forward. If

not, the moving direction varies depending on the start position to be

dangerous.

The tension operation from a coordinate (less than 30mm = 80 – 50 in the

above example) located before the end position (30mm) changes to the

pressing operation from the current position to the tension end position.

Note that the tension operation after positioning to the position of 80mm

does not take place.

(3) The work is pulled also after completion of the tension. The work is drawn

back or pulled further if the work is moved. When the work is drawn back

before the approach position, alarm code 0DC “pressing operation range

over error” occurs to stop the work. When the work is moved in the tension

direction and the load current becomes less than the current limit value

(pressing in percent), PE* is turned OFF. The work reaches the tension

moving distance set in “Positioning width” to cause miss-pressing.

Pressing Operation

ST*: Start position

ST*

ST*

ST*

Tension Operation

Approach Operation

Tension Operation

Tension start position

80mm

Temsion end position

80 – 50 = 30mm