IAI America ERC3 User Manual

Page 277

Advertising
background image

Chapter 4 Operation

4.4 Operation in MEC Mode 1 and 2 (Operation with PLC)

267

[6] Operation when Operation Pattern is “2-Point Stop (2-Point Positioning)”

(1) Home Return (ST0, HEND, LS0, LS1, PE1)

If the home-return operation is not performed with the operation panel, it will be performed

with Movement Signal 1 to the first end point ST0. The actuator moves to the end point after

home-return and then stops (for positioning).

Move signal 1 ST0

Home return completion HEND

Detection of end position LS1

(Note 1)

Actuator operation

Reverse at

mechanical end

Home position End position

Note 1 If “Use Pressing Function” is selected in the initial setting, this signal becomes

the end point positioning complete signal PE1.

(2) Positioning Operation (ST0, LS0, LS1, PE0, PE1)

Positioning is at the end point when Movement Signal 1 ST0 is ON, and goes back to start

point (positioning) when it is OFF.

Move signal 1 ST0

Detection of start position LS0

(Note 1)

Detection of end position LS1

(Note 1)

Actuator operation

End position

Start position

Note 1 If “Use Pressing Function” is selected in the initial setting and the positioning is

performed, this signal becomes the positioning complete (LS0 ĺ PE0, LS1 ĺ

PE1). If the operation pattern is “3-point stop (3-Point Positioning)”

Advertising