IAI America ERC3 User Manual

Page 145

Advertising
background image

Chapter 3 Wiring

3.5 MEC Mode 2 (Operation Using PIO Converter)

135

(2) External Drive Cutoff Relay Type

Note 1

When the teaching pendant is not connected, S1 and S2 become short-circuited inside the

controller.

Note 2

For CR1, select the one with coil current 0.1A or less.

Note 3

The motor driving power line MPI that is to be turned ON/OFF at contact CR2 and the load

current of the emergency stop signal EMG(-) are follows;

ERC3 high output setting valid: 3.5A (MAX. 4.2A)

Load current

ERC high output setting invalid: 2.0A

During in-rush 8.3A

[Refer to 10.3 for the compliance with Safety Categories.]

Caution:

• Do not attempt to cut the 0V circuit of GND whit the emergency stop. Doing so may burn the

internal circuit. If an absolute shutoff of the power supply is required, conduct it on the primary

side of DC power supply (alternating current side).

• In case the power source for each controller is different, join the 0V of each power supply

together.

CR1

(Note 2)

CP24V

GND

S2

MPO

Motor power

supply

PIO Converter

CR1

S1

S2

S1

S2

S1

CR2

CR1

PIO Converter

1st unit

24V

0V

PIO Converter

2nd unit

(Note 1)

Control

power supply

PIO

Converter

2nd unit

PIO

Converter

Nth unit

Emergency

stop signal

ERC3

GND

CR2

(Note 3)

CP24V

MPI

MPO

EMG (-)

CR2

PIO Converter

Nth unit

GND

CP24V

MPI

MPO

EMG(㧙)

CR2

GND

EMG (-)

MPI

GND

CP24V

MPI

MPO

EMG (-)

Emergency-stop

switch on the teaching

pendant

Emergency stop

reset switch

Emergency

stop switch

Advertising