Chapter 4 Operation

4.2 Operation in Positioner Mode

4.2.2 Operation in Positioner Mode 1

164

4.2.2 Operation in Positioner Mode 1

In Positioner Mode 1, it is available to select 3 types of PIO patterns with the parameters. This

PIO Pattern cannot be switched over after the system is finished to be established or during the

actuator operation. Choose the optimum pattern beforehand considering the system operation

specifications and prepare the cables and sequence design.

[1] PIO Pattern Selection and Main Functions

{

: Valid function

PIO Pattern

(Parameter No.25)

0

1

2

Mode

8-point type Solenoid valve

type

16-point type

Number of positioning

points

8

3

16

Operation with the Position

No. Input

{

u

{

Position No. direct

command operation

u

{

u

Positioning

{

{

{

Velocity change during the

movement

{

u

{

Pressing (tension)

{

{

{

Pitch Feeding

(relative moving feed)

{

{

{

Home return signal input

{

u

u

Pause

{

{

{

Brake release signal input

{

{

{

Zone signal output

{

u

{

Note 1

M

aj

or

fu

nc

tio

ns

Position zone signal output

u

u

{

Note 1

Note 1 The position zone signal output (set in delivery) can be switched to the zone signal

with Parameter No.149. This cannot be used together with the zone signal.