Chapter 7 troubleshooting 7.4 alarm list – IAI America ERC3 User Manual

Page 375

Advertising
background image

Chapter 7

Troubleshooting

7.4
Alarm List

365

Alarm

Code

Alarm

Level

Alarm Name

Cause/Treatment

Positioner

Mode 1

Pulse

Train

Control

Mode

Positioner

Mode 2

MEC

Mode 1

MEC

Mode 2

0A7

Oper

ation releas

e

Command

deceleration

error

Cause

: Because there is not enough

deceleration distance when the

deceleration is changed to a lower

setting during the operation, the

actuator exceeded the soft limit when

deceleration was made from the

current position with the deceleration

after the change.

Soft limit

Deceleration starting position

not resulting in soft limit overshoot

If a command is issued here,

soft limit overshoot will occur.

The cause is that the timing to make

the next movement command when

the speed was changed during the

operation was late.

Treatment : Make the timing earlier for the

movement command for the

deceleration speed change.

{

{

{

{

0A8

C

ol

d s

ta

rt

Unsupported

motor/encoder

types

Cause

: Motor or encoder cannot be identified.

Treatment : Please contact us if the alarm is

issued even with the applicable

actuator and the same problem

happens again even after rebooting

the power.

{

{

{

{

Advertising