Chapter 4 Operation

4.2 Operation in Positioner Mode

4.2.2 Operation in Positioner Mode 1

196

 

Caution: (1) At occurrence of an alarm in the release level

Note 1

, RES can reset

the alarm. Cancel the remaining moving distance after confirmation

that alarm signal *ALM (being ON in normal state and OFF at

occurrence of an alarm) is set to ON.

(2) If *STP is turned OFF when the actuator is in a positioning complete

condition, PE* would not turn OFF.

Note 1 Refer to Chapter 8 Troubleshooting for details of alarms.



II. Use of start signal ST*

„

Control method

It is available to pause the operation if turning OFF the start signal ST* during the operation.

Use the control method for interlock in case where an object is invaded into the moving

direction of the actuator being moved.

1) If the ST* signal is turned OFF during movement, the actuator is paused. The deceleration

is the value set in the position table.

2) ST* Signal being turned OFF is identified as a cancel of positioning. PE* would not turn

ON.

3) If the ST* signal is turned ON again, the remaining movement is continued. The

acceleration is the value set in the position table.

Before operation

Positioning

complete state

Operation

Temp.

stop

Cont.

Op.

Position

complete

Start signal

ST*

(PLCĺController)

Operation of actuator

PE* not

turned ON

Current position No.

PE*

(ControllerĺPLC)

Velocity

Positioning

Completion

Signal Output

1)

2)

3)

4)

5)

1)

3)

4) 5)

2)