IAI America ERC3 User Manual

Page 67

Advertising
background image

Chapter 1 Specifications Check

1.2 Specifications

1.2.1

Actuator

57

• RA6C

Pressing Force [N]

Current Limit Value [%]

Ball Screw Lead [mm]

20

30

40

50

60

70

4

312 469 625 781 937 1094

8

156 234 312 391 469 547

16

78

117 156 195 234 273

24

52

78 104 130 156 182



RA6C Current Limit Values and Pressing Force

Pressing Force [N]

Current Limit Value [%]

0

200

400

600

800

1000

1200

0 10 20 30 40 50 60 70 80

Lead 8

Lead 4

Lead 4

Lead 16

Lead 16

Lead 24

Lead 24





 

Caution: (1) The relation of the current limit and the pressing force is a reference

assuming when the speed is 20mm/s.

(2) There will be a little variance in the actual pressing force. If the value of

current limit is small, the variance for the pressing force becomes big.

(3) Use the product with the current limit within the range specified in the

graph. If used below 20%, the pressing force would not be stable. An

operation may not be made in some cases. An operation cannot be made

also when it is beyond 70%. If use in such a condition, it may extremely

shorten the product life by the degradation of insulator in the motor coil due

to heat generation.

(4) When the approaching speed (setting in the position table) to the pressing

start position is 20mm/s or less, the pressing operation will be made with

the approaching speed. In this case, also, the pressing force would not be

stable. In such cased, check in advance that the actuator can be used with

no problem before start using.

Advertising