Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

324

(39) Default stop mode (Parameter No.53)

No.

Name

Symbol

Unit

Input Range

Default factory setting

53 Default stop mode

CTLF

0 to 7

0 (Does not use)

This parameter defines the power-saving function. [Refer to Chapter 5 Power-saving Function.]

(40) Position-command primary filter time constant (Parameter No.55)

No.

Name

Symbol

Unit

Input Range

Default factory setting

55

Position-command primary

filter time constant

PLPF

msec

0.0 to 100.0

0

Use this in the case to set the value in “Acceleration/Deceleration” box in the position table to 2

“1-step delay filter”, or in the case that there is no acceleration/deceleration function the host

controller in Pulse Train Control Mode.

The primary delay filter is disabled if “0” is set.

The greater the setting value is, the longer the delay is and the slower the

acceleration/deceleration is. Even though the impact at acceleration and deceleration are

reduced, longer time is required especially for the operation end, thus the cycle time will be

extended.

Refer to 4.3 [9] (1) Position command primary filter time constant for the details of Pulse Train

Control Mode.

Velocity