3 axis no. setting – IAI America ERC3 User Manual

Page 402

Advertising
background image

Chapter 10

Appendix

10.2 W

ay to Set Multiple Controllers with 1

Teaching

Tool

392

10.2.2 Detailed Connection Diagram of Communication Lines

SIO Converter

4-way Junction (Manufactured by AMP : 5-1473574-4)

(SGA) A

(SGB) B

0V

1
2

3

1
2

7

1
2

7

1
2

3

1
2

3

4

1
2

3

4

1
2

3

4

Personal

Computer

Touch Panel Teaching

J4, J5

Mini DIN

8 pin

Double Shield Cable

(Note 1)

Recommended : Taiyo Cabletec Corp.

HK-SB/20276XL

(AWG22)

e-CON Connector

(Manufactured by AMP : 4-1473562-4)

Cover Color : GN

Controller

Link Cable

CB-RCB-CTL002

ERC3 2nd Unit

SIO Connector

SIO Connector

Class D grounding

ERC3 1st Unit

e-CON Connector

(Manufactured by AMP :

4-1473562-4)

Housing Color : GN

e-CON Connector

(Manufactured by AMP : 3-1473562-4)

Cover Color : OR

Controller

Link Cable

CB-RCB-CTL002

YW

OR

BL

YW

OR

BL

SGA
SGB

GND

SGA

SGB

GND

(A)

(B)

SGA
SGB

0V

Shield

(Note 1) Apply a 2-pair shielded cable.

When connecting a cable other than recommended to (A) and (B), make sure to use a

hard-cored cable equivalent to the vinyl cable (KIV) dedicated for control devices with

the sheath outer diameter from 1.35 to 1.60mm. Using cables with outer diameter out

of the specification may cause poor contact to occur.

Caution: When cables with outer diameter out of the specification are used, use a

terminal block instead of 4-direction junction. In this configuration, disconnect

the e-CON connector of the link cable. If an error possibly caused by poor

contact occurs frequently, replace the junction with the terminal block.

10.2.3 Axis No. Setting

Connect the PC software or teaching pendant and select the axis number.

Supply power to the controller only for the set axis number.

Caution: The axis number must be unique.