IAI America ERC3 User Manual

Page 335

Advertising
background image

Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

325

(41) S-motion rate (Parameter No.56)

No.

Name

Symbol

Unit

Input Range

Default factory setting

56 S-motion rate

SCRV

%

0 to 100

0

This parameter is used when the value in the “Acceleration/deceleration mode” field of the

position table is set to “1 [S-motion]”.

This enables to ease the impact at acceleration and deceleration without making the takt time

longer.

Velocity

Time

0

Swing width

Acceleration time

The S-motion is a sine curve that has the acceleration time as 1 cycle.

The level of its swing width can be set by this parameter.

Setting of Parameter No.56 [%] Level of swing width

0 [Set in delivery]

No S-motion (Dotted line shown in the image below)

100

Sine curve swing width × 1 (Double-dashed line shown in the image

below)

50

Sine curve swing width × 0.5 (Dashed line shown in the image below)

10

Sine curve swing width × 0.1 (Solid line shown in the image below)

Velocity

Time

Setting: 10

Setting: 50

Setting: 100

0

within 2 seconds

(Caution (3))

Caution: 1) If the S-motion is specified in acceleration/deceleration mode, executing

position command or direct value command while the actuator is moving

causes an actuator to move along the trapezoid pattern. To change a

speed during operation, be sure to specify such a position command while

the actuator is in pause state.

2) If acceleration time or deceleration time exceeds 2 seconds, do not specify

S-motion control. The actuator will fail to operate normally.

3) Do not perform temporary stop during acceleration or deceleration. The

speed change (acceleration) may cause the dangerous situation.

Advertising