3 i/o parameter – IAI America ERC3 User Manual

Page 313

Advertising
background image

Chapter 6

Adjustment of Operation

6.3 I/O Parameter

303

6.3 I/O Parameter

Parameter data should be set appropriately according to the applicaiton requirements.

When a change is required to the parameters, make sure to back up the data before the change

so the settings can be returned anytime.

With using PC software, it is able to store the backup to the PC.

Leave a memo if using the teaching pendant.

For a quick data recovery after such works as investigation on malfunction and replacement of

ERC3 and PIO converter, it is also recommended to back up or take a note on the parameter

after the setting change.

The change to the parameters will be activated after they are edited, written to the FeRAM, then

either software reset or reboot of the power. It will not be active only with writing on the teaching

tool.

Warning: Establishment of parameter setting gives a great influence to operation.

Wrongly established setting could cause not only an operation error or

malfunction, but also it is very dangerous.

Settings at the delivery enable the product to operate standardly.

Understand very well about the control logic of ERC3 and PIO converter

if making a change or performing a setting suitable to the system.

Please contact us if you have anything unclear.

Do not attempt to turn OFF the power to the ERC3 or PIO converter

while writing the parameters.