[3] Servo Adjustment

The parameters are preset at the factory before shipment so that the actuator operates stably

within the rated (maximum) transportable weight.

However, the preset setting cannot always be the optimum load condition in the actual use. In

such cases, servo adjustment may be required.

This section describes the basic servo adjustment method.

No.

Situation that requires

adjustment

How to Adjust

Takes time to finish

positioning

Positioning accuracy is

not appropriate

1

Shorter cycle time is

desired

Ɣ Increase the value of Parameter No.3 “Servo gain number”. By

setting a larger value, the follow-up ability to the position

command becomes better. Set the value to any of 3 to 10

roughly or up to 15 at the maximum. If the value is too large, an

overshoot is caused easily and may cause noise or vibration.

For the velocity loop proportional gain parameter, the parameter

number differs depending on the setting of enable/disable of

Gain Scheduling and the high output setting.



Shown below is the table of velocity loop proportional

gain parameter numbers that are enable.

High Output Setting (Parameter No.28)

1 (Enable)

0 (Disable)

Parameter No.29

Parameter No.5

2 Vibration is generated at

acceleration/deceleration

Ɣ The cause of the problem is excessive

“acceleration/deceleration setting” or vulnerable structure of the

unit on which the actuator is installed. If possible, reinforce the

unit itself, first.

Ɣ Decrease the values of “acceleration/deceleration setting”.

Ɣ Decrease the number of Parameter No.3 “Servo gain number”.

If the Parameter No.3 “Servo gain number” is too low, it takes

long time to finish the positioning.

Caution: Rapid and excessive settings are dangerous. They may devices including the

actuator to be damaged and/or people to be injured. Take sufficient note on

the setting.

Record settings during servo adjustment so that prior settings can always be

recovered.

When a problem arises and the solution cannot be found, please contact IAI.