Chapter 1 Specifications Check

1.2 Specifications

1.2.1

Actuator

55

• SA7C

Pressing Force [N]

Current Limit Value [%]

Ball Screw Lead [mm]

20

30

40

50

60

70

4

192 288 385 481 577 673

8

96 144 192 240 288 336

16

48

72

96

120 144 168

24

32

48

64

80

96

112



0

100

200

300

400

500

600

700

800

Pressing Force [N]

Current Limit Value [%]

SA7C Current Limit Values and Pressing Force

0 10 20 30 40 50 60 70 80

Lead 4

Lead 4

Lead 8

Lead 8

Lead 16

Lead 16

Lead 24

Lead 24





 

Caution: (1) The relation of the current limit and the pressing force is a reference

assuming when the speed is 20mm/s.

(2) There will be a little variance in the actual pressing force. If the value of

current limit is small, the variance for the pressing force becomes big.

(3) Use the product with the current limit within the range specified in the

graph. If used below 20%, the pressing force would not be stable. An

operation may not be made in some cases. An operation cannot be made

also when it is beyond 70%. If use in such a condition, it may extremely

shorten the product life by the degradation of insulator in the motor coil due

to heat generation.

(4) When the approaching speed (setting in the position table) to the pressing

start position is 20mm/s or less, the pressing operation will be made with

the approaching speed. In this case, also, the pressing force would not be

stable. In such cased, check in advance that the actuator can be used with

no problem before start using.