Chapter 3 Wiring

3.6 MEC Mode 3 (Solo Operation with Quick

Teach)

140

[2] RCM-PST-1

Note 1 ƑƑƑ indicates the cable length. (Example) 030 = 3m

Caution:

In case it is necessary to use a terminal block in an electromagnetic control box, cut off the 3P

plug to connect the line.

In that case, do not attempt to share the ground line with other devices or join with others.

For the wiring, follow the cable colors described below.

Electric wire

color

Signal Name

Description

BR

L

BL

N

Power supply

YW & GN

PE

Ground wire

Connect it to a power socket with a grounding

electrode.

If socket is not with a grounding electrode, use a

3P-2P conversion adopter and plug into 2P

power socket. Connect the ground line to a

ground terminal near the socket.

Otherwise, cut the cable and connect it using a

terminal block in an electromagnetic control

box.

Accessory Cable for ERC3

CB-ERC3S-PWBIOƑƑƑ

(Note 1)

Power Supply

24V DC

External emergency stop signal

(always closed and open in

emergency stop)

3P-2P

Converter Adapter

RCM-PST

Other

equipment

RCM-PST

Other

equipment

Other

equipment