5] home return circuit – IAI America ERC3 User Manual

Page 423

Advertising
background image

Chapter 10

Appendix

10.5
Example of Basic Positioning Sequence

(PIO Patterns 0 to 3 in PIO Converter)

413

[5] Home Return Circuit

040

046

049

051

IN4

OUT11

OUT11

IN12

IN13

IN12

OUT1

OUT11

HOMES

HOME

OUT4

HOMEL

Home

Return

HOME

Home Return

HOME

Home

Return

Home Return

Display

Aux. 2

Home Return

Display

Aux. 1

Home Return

Display

Aux. 1

HEND

Home Return

Complete

PEND

Point

Positioning

Completion

HEND

Home

Return

Completion

STARTL

RC Start

Display

Home Return

<1.11>

b010 a042 a046

Home Return

Dispaly Aux. 1

a049 a051

Home Return

Dispaly Aux. 2

Home Return

Dispaly

b047

(Interlock)

This disables home return

during continuous operation.

While the “Home return” signal is

ON, these repeat ON/OFF at

intervals of 200 ms.

(Interlock)

Turns the “Home return” signal OFF at completion of home return.

It is set as it would not be able to home return again after the home return

operation is complete unless “Home Return Complete” signal turns OFF.

Similar to the operation circuit, this is

used to determine whether the controller

can be operated.

(Confirmation of ready status of controller)

The “Home return” lamp blinks during home return

and goes on at the “Home return complete” signal.

TIM3

TIM2

TIM2

200ms

is set to

TIM2

200ms

is set to

TIM3