2.2 Installation and Storage Environment

71

2.2 Installation and Storage Environment

This product is capable for use in the environment of pollution degree 2

*1

or equivalent.

*1 Pollution Degree 2 : Environment that may cause non-conductive pollution or transient

conductive pollution by frost (IEC60664-1)


[1] Installation Environment

(1) Actuator

Do not use this product in the following environment.

In general, the installation environment should be one in which an operator can work without

protective gear.

Also provide sufficient work space required for maintenance inspection.

• Where the actuator receives radiant heat from strong heat sources such as heat treatment

furnaces

• Where the surrounding temperature exceeds the range of 0 to 40°C

• Where the temperature changes rapidly and condensation occurs

• Where the relative humidity exceeds 85% RH

• Relative humidity less than 10%RH (Quick Teach)

• Where the actuator receives direct sunlight

• Where the actuator is exposed to corrosive or combustible gases

• Where the surrounding air contains a large amount of powder dust, salt or iron (at level

exceeding what is normally expected in an assembly plant)

• Where the actuator is subject to splashed water, oil (including oil mist or cutting fluid) or

chemical solutions

• Where the actuator receives impact or vibration

If the actuator is used in any of the following locations, provide sufficient shielding measures:

• Where noise generates due to static electricity, etc.

• Where the actuator is subject to a strong electric or magnetic field

• Where the actuator is subject to ultraviolet ray or radiation

(2) PIO Converter • Quick Teach

Do not use this product in the following environment.

• Where the surrounding temperature exceeds the range of 0 to 40°C

• Where the temperature changes rapidly and condensation occurs

• Where the relative humidity exceeds 85% RH (10 to 85%RH for Quick Teach)

• Where the actuator is exposed to corrosive or combustible gases

• Where the surrounding air contains a large amount of powder dust, salt or iron䎃

• Where the actuator receives impact or vibration

• Where the actuator receives direct sunlight

• Where the actuator is subject to splashed water, oil or chemical solutions

If the actuator is used in any of the following locations, provide sufficient shielding measures:

• Where noise generates due to static electricity, etc.

• Where the actuator is subject to a strong electric or magnetic field

• Location with the mains or power lines passing nearby