Chapter 4 Operation

4.2 Operation in Positioner Mode

4.2.3 Operation in Positioner Mode 2 (Operation Using PIO Converter)

237

 

Caution: (1) At occurrence of an alarm in the release level

Note 1

, RES can reset the

alarm. Cancel the remaining moving distance after confirmation that

alarm signal *ALM (being ON in normal state and OFF at occurrence

of an alarm) is set to ON.

Note 1: [Refer to 4.4 Alarm List for details of alarms.]

(2) Turning *STP OFF with the actuator being in the positioning

complete state causes PE* and PEND to be turned OFF. Note that

this situation may not occur when a sequence program is created.

II. Use of start signal ST*

„

Control method

For PIO converter, it is available to pause the operation if turning OFF the start signal ST*

during the operation.

Use the control method for interlock in case where an object is invaded into the moving

direction of the actuator being moved.

1) If the ST* signal is turned OFF during movement, the actuator is paused. The deceleration

is the value set in the position table.

2) Turning the ST* signal OFF causes the positioning to be interrupted and deemed complete

signal PEND to be turned ON.

3) If the ST* signal is turned ON again, the remaining movement is continued. The

acceleration is the value set in the position table.

Before

operation

Positioning

complete state

Operation

Temp.

stop

Cont.

Op.

Position

complete

Start signal

ST*

(PLCoController)

Positioning completion signal

PEND

(ControlleroPLC)

Operation of actuator

PE* not

turned ON

Current position No.

PE*

(ControlleroPLC)

PEND turned

ON

Velocity

Positioning

Completion

Signal Output

1)

2)

3)

4)

5)

1)

3)

4) 5)

2)

Deceleration

and stop with

Start signal for

position 1

tuirned OFF

Movement

restart with

Start signal for

position 1

tuirned ON