Chapter 2 Installation

2.3 How to Install

82

• When Using Flange Bracket (Option)

When installing the unit with using the flange bracket, use the tapped holes as for the direct

installation and affix with hex socket head cap screws.

Regarding attachment screws

• Use of high-tension bolts meeting at least ISO-10.9 is recommended.

• For the effective engagement length between the bolt and female thread, provide at least the

applicable value specified below:

Female thread is made of steel material ĺ Same length as the nominal diameter

Female thread is made of aluminum ĺ 1.8 times of nominal diameter

Caution: Pay attention when selecting screws. If a bolt out of the instruction is used, it may

cause damage on tapped holes or unexpected accident or failure due to insufficient

strength on the actuator attachment.

Tightening Torque [N•m]

Actuator

Type

A

B

C

D

E

F

Mounting

Screw

If the platform to

attach actuator

is steel

If the platform to

attach actuator

is aluminum

RA4C 44.5 75

10

34

60 I6.6 through

hole

M6

12.34

5.36

RA6C 63.5 99

12

50

82

I

9 through

hole

M8

29.97

11.48

A

E

C

D

B

4-F