3] absolute battery – IAI America ERC3 User Manual

Page 308

Advertising
background image

Chapter 6

Adjustment of Operation

6.1

Absolute Reset and

Absolute Battery

298

[3] Absolute Battery

In PIO Converter for Simple Absolute Type, there are a battery for Absolute Type and fabric

hook-and-loop faster enclosed.

Separate the fastener and attach each to side surface of PIO Converter and the battery for

Absolute Type. Join the fastener attached on the absolute battery and that on PIO Converter to

fix them together. Connect the battery to the absolute battery connector on the bottom of the

battery PIO Converter.

(1) Absolute Battery Type

Item

Specifications

Battery model

AB-7

Battery voltage

3.6V

Current capacity

3300mAH

Reference for battery replacing timing

(Note 1)



Approx. 3 years

(It varies significantly by the effects of the

usage condition)

(Note 1) Replace the battery regularly.

(2) Absolute Battery Charge

Please have the battery charged for more than 72 hours before using for the first time or after

replacing with a new one. The battery gets charged while the controller is supplied with 24V

power.

It is possible to retain the encoder data for the duration shown below for each hour of battery

charge.

Data Holding Time

Value for User Parameter No.155

0

1

2

3

Data holding time per hour of battery charge time

(Note 1)

(reference)

6.6H

5.0H

3.3H

1.6H

Holding time when fully charged

(Note 1)

(reference)

20

days

15

days

10

days 5 days

(Note 1) Followings are the reference values of time assuming the battery is new.

Leaving the controller power OFF for more than the data holding time will lead to a loss of the

data. Have the battery charged as early as possible.

Caution: There is life to the battery and the duration for data holding will

decrease. Replace the battery with a new one if the retaining time is

remarkably dropped even with enough charging time.

Advertising