3] list of pio signals – IAI America ERC3 User Manual

Page 122

Advertising
background image

Chapter 3 Wiring

3.3 Positioner Mode 2 (Extension

Type by PIO Converter)

112

[3] List of PIO Signals

The table below lists the functions of PIO signals. The detail of each signal is provided in this

chapter. Refer to the relevant sections shown in the list below.

Category

Signal

Abbreviation

Signal Name

Function Description

Relevant

Sections

CSTR

PTP Strobe

(Start signal)

The actuator will start to move to the position set by the

command position number.

4.2.3 [6]

PC1 to

PC256

Command Position

Number

Input (in binary) a number of the position that is desired to

move.

4.2.3 [6]

BKRL

Brake Forcible Release The brake will forcibly be released.

4.2.3 [5]

*STP

Pause

When this signal is turned OFF while in move, the actuator

decelerates and then stops. The remaining movement is in a

hold while the actuator is stopped and will resume when the

signal turns back ON.

4.2.3 [6]

RES

Reset

An alarm will be reset when this signal is turned ON. Also, when

it is turned ON in the pause mode (*STP is turned OFF), the

remaining movement amount can be cancelled.

4.2.3 [5]

SON

Servo ON

The servo remains ON while this signal is ON, or OFF while this

signal is OFF.

4.2.3 [5]

HOME

Home Return

The controller will perform home return operation when this

signal is turned ON.

4.2.3 [5]

MODE

Teaching Mode

The operating mode will change to the teaching mode when

this signal is turned ON. It cannot be switched over unless all of

CSTR, JOG+ and JOG- since the actuator is in a stop condition

(excluding the pause condition).

4.2.3 [6]

JISL

Jog/Inching Selector

Jog Operation can be performed with JOG+ and JOG- while

this signal is OFF.

Inching Operation is performed with JOG+ and JOG- when it is

ON.

4.2.3 [6]

JOG +

JOG -

Jog

JOG operation is performed to the positive direction when

JOG+ Signal is ON and to negative when JOG- Signal is ON

while JISL Signal is turned OFF.

Inching operation will be performed to the positive direction

when JOG+ Signal is ON and to negative when JOG- Signal is

ON while JISL Signal is turned ON.

4.2.3 [6]

PWRT

Current Position Write

While in Teaching Mode, if the command position number (PC1

to PC32) is indicated and this signal is turned ON for 26ms or

more, the current position is written to the indicated position

number.

4.2.3 [6]

Input

ST0 to ST6 Start Signal

With the start signal of each position, while in Electromagnetic

Valve Mode, the actuator moves to the position corresponding

to the start signal if this signal is turned ON.

4.2.3 [7], [8]