Chapter 4 Operation

4.4 Operation in MEC Mode 1 and 2 (Operation with PLC)

259

4.4 Operation in MEC Mode 1 and 2 (Operation with PLC)

There are two types of operation modes in MEC Mode, 2-point stop and 3-point stop, and

2-point stop performs the same operation as of Single Solenoid while 3-point stop possesses a

function of intermediate stop in addition to the operation same as that of Double Solenoid.

ERC3 is controlled with PIO directly in MEC Mode 1 and via PIO Converter in MEC Mode 2,

however, the operation method is the same for both modes. MEC Mode 2 is applicable for

Simple Absolute Type.

In this mode, Quick Teach can be used.

These teaching tools listed below are also able to be used.

(1) MEC PC Software

(2) Touch Panel Teaching

[1] Outline for Operation Patterns and Functions

The settings for the operation patterns and operational conditions are to be established in a

teaching tool. For the details, refer to each instruction manual.

Operation Pattern

Overview

Stopping at 2 points

(2-point positioning)

[Single-solenoid mode]

Movement by 1 input

between 2 points

Air cylinder can perform a 2-point movement with

the control same as when operating Single

Solenoid.

You can set the positions of the end point and start

point.

You can specify the moving speed and

acceleration/deceleration.

[Double-solenoid mode]

Movement by 2 input

between 2 points

Stopping at 3 points

(3-point positioning)

[3-point positioning]

Movement by 2 input

between 3 points

Air cylinder can perform a 2-point movement with

the control same as when operating Double

Solenoid.

You can set the positions of the end point and start

point.

You can set the position of an intermediate point

and perform positioning to the intermediate point.

You can specify the moving speed and

acceleration/deceleration.