Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

313

(12) SIO communication speed (Parameter No.16)

No.

Name

Symbol

Unit

Input Range

Default factory setting

16 SIO communication speed

BRSL

bps

9600 to 230400

38400

Set the SIO baud rate for the startup.

Set an appropriate value in accordance with the communication speed of the host.

Communication speed can be set from 9600, 14400, 19200, 28800, 38400, 76800, 115200 or

230400bps.

Caution: After the PC software is connected, the baud rate setting is changed to that of

the PC software. To make effective the value set in the parameter, turn off the

power once and on it again.

(13) Minimum delay time for slave transmitter activation (Parameter No.17)

No.

Name

Symbol

Unit

Input Range

Default factory setting

17

Minimum delay time for slave

transmitter activation

RTIM

msec

0 to 255

5

In this setting, set the time from receiving the command (received data) during the SIO

communication till the response (sent data) is returned

(14) Servo ON input disable (Parameter No.21)

No.

Name

Symbol

Unit

Input Range

Default factory setting

21 Servo ON input disable

FPIO

0 : Enabled

1 : Disabled

0

This parameter defines whether the servo ON input signal is disabled or enabled.

Set this parameter to “1” if servo ON/OFF is not provided by PIO signals.

When the servo ON input signal is disabled, the servo is turned ON as soon as the controller

power is turned ON.

Also, operation becomes available with no servo-on signal input being connected.

Set Value

Description

0

Enable (Use the input signal)

1

Disable (Does not use the input signal)