IAI America ERC3 User Manual

Page 332

Advertising
background image

Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

322

(31) Enable function (Parameter No.42)

No.

Name

Symbol

Unit

Input Range

Default factory setting

42 Enable function

FPIO

0 : Enabled

1 : Disabled

1

Set valid/invalid the deadman switch function if the teaching pendant is equipped with a

deadman switch.

Set Value

Description

0

Enable (Use the input signal)

1

Disable (Does not use the input signal)

(32) Silent interval magnification (ParameterNo.45)

No.

Name

Symbol

Unit

Input Range

Default factory setting

45 Silent interval magnification

SIVM

times

0 to 10

0

It is not necessary to change the parameter if a teaching tool such as PC software is to be used.

(33) Velocity override (Parameter No.46)

No.

Name

Symbol

Unit

Input Range

Default factory setting

46 Velocity override

OVRD

%

0 to 100

100

When move commands are issued from the PLC, the moving speed set in the “Velocity” field of

the position table can be overridden by the value set by this parameter.

Actual movement velocity = [Velocity set in the position table] × [setting value in Parameter No.46]

Example) Value in the “Velocity” field of the position table: 500mm/s

Setting in Parameter No.46 20%

In this case, the actual movement speed becomes 100mm/s.

The minimum setting unit is 1% and the input range is 1 to 100%.

(Note) This parameter is ignored for move commands from a teaching tool such as PC

software.

(34) PIO jog velocity 2 (Parameter No.47)

[Refer to Parameter No.26 PIO jog velocity]